歡迎訪問:河北省微生物研究所有限公司
全國服務熱線
0312-3037815
TTC檢測板

TTC檢測板

添加時間:2018-11-07 08:59:28  瀏覽次數(shù):

TTC/M微生物檢測板說明
  TTC/M微生物檢測板榮獲國家發(fā)明專利和河北省科技進步獎。是利用特定培養(yǎng)基提供用于一次完成細菌、霉菌/酵母菌菌落總數(shù)測定的檢測裝置,它使繁鎖的微生物檢驗從實驗室的束縛中解放出來,直觀、準確、便捷地將測定結(jié)果展現(xiàn)在用戶面前。該產(chǎn)品不需要專用的實驗室和大型儀器而能夠快速、簡便、適合于大數(shù)量微生物標本測定的檢測裝置,用于測定細菌菌落總數(shù),霉菌和酵母菌總數(shù)的測定。本項目涉及微生物檢驗、化工合成、模型設(shè)計等多項技術(shù),廣泛應用于水處理、化工、造紙、涂料、皮革漿料等生產(chǎn)行業(yè),對加強環(huán)境監(jiān)控,保持水源潔凈,有效控制飲食衛(wèi)生,提高企業(yè)產(chǎn)品質(zhì)量都有深遠意義,市場前景十分廣闊

TTC/M DIPSLIDES
TEST FOR TOTAL BACTERIA COUNT,YEASTS AND MOULDS

TTC/M Dipslides are a combination slide for the detection of bacteria,yeasts and moulds in fluid and on surfaces. These slides provide a simple`means of enumerating these micro-organisms in industrial and environmental applications. TTC/M Dipslides find particular application for monitoring cooling water and similar recirculating water systems, natural waters and effluents and industrial cutting fluids. The range of detection for bacteria and yeasts is 101 – 106 CFU/ml for fluids. The range of detection for moulds is 101 – 103 CFU/ml for fluids.

PRINCIPLE
TTC/M Displides comprise a simple agar slide contained in a plastic test tube. The lighter color medium comprises nutrient agar for total aerobic count of bacteria(plate count). The medium contains dye which stains most colonies red for easy enumeration. The darker coloured medium comprises malt agar from the growth of yeast and moulds. Yeast appear as low round white or grey discs, moulds appear as furry colonies. After incubation the side surface are simply compare against the appropriate comparison chart to obtain the bacteria, yeast or mould count.

INSTRUCTIONS FOR USE
Test Fluids
l. Hold the Dipslide by the cap and remove from the tube. Do not touch the culture medium.
2 Immerse the slide in the fluid to be tested for about 1 0 seconds. Alternatively expose the slide to a spray or running fluid so that the slide surfaces are covered. 
3 Remove the slide from the fluid and allow it to drain for a few seconds.
4 Replace the Dipslide into the tube and twist to tighten the cap. Label the tube the identification label supplied. Incubate the slide as directed later.
Incubation
After the slides have been inoculated as above they must be incubated to allow the growth of bacteria, yeasts or mould. For precise enumeration of organisms, it is important to incubate at the correct temperature. The growth of bacteria requires a different incubation temperature to that for the growth of yeasts and moulds. If enumeration of bacteria, yeast and moulds are required then it is recommended that two dipslides be inoculated and each incubated at the appropriate temperature stated below: 
Bacteria : incubate at 35 - 37℃ for two days.
Yeasts and Moulds: incubate at 27 – 30℃ for two days. Note that higher temperatures may inhibit the growth. In the case of negative results, incubation for a further five days can be carried out to detect any slow growing strains.
If it is required merely to detect the presence of micro-organisms or only to get an approximate enumeration, then the slides can simply be stood in a warm place and examined after two days. If the temperature is considerably lower, than the temperatures stated above, microbial growth may be slow and it is advisable to continue incubation for a further period to detect the presence of organisms.

INTERPRETATION OF RESULTS
Compare the slide surfaces against the comparison charts printed opposite. Read the result corresponding to fluids or surfaces as appropriate. Note that very high levels of organisms could lead to a confluent growth and could be recorded as a nil result. Compare against an unused slide when leading results.